MODEL | EA33KTLSI | EA40KTLSI |
INPUT (DC) | ||
Max. DC input power | 33800 W | 40800 W |
Max. DC input voltage | 1000 V | |
Starting voltage | 200 V | |
Max. DC input current | 3 × 23 A | |
MPP voltage range | 320 ~ 900 V | |
Full-load MPP voltage range | 480 ~ 800 V | 580 ~ 850 V |
Number of MPP inputs | 3 | |
Nominal DC input voltage | 620 V | 680 V |
DC terminals | 2 × 6 | |
MPPT efficiency (static) | > 99.9% | |
Withstanding voltage & insulation for DC input against the enclosure | Basic insulation 3000 Vdc / 1 min | |
OUTPUT (AC) | ||
Rated output power | 30 KW | 36 KW |
Max. apparent power | 33 KVA | 40 KVA |
Rated output voltage | 3 × 380 / 400 / 415 Vac +N+PE | 3 × 277 / 480 Vac +PE |
Rated output current | 3 × 45.9 A | |
Max. allowable output current | 3 × 48 A | |
Rated frequency | 50 Hz / 60 Hz | |
DC component | < 0.5% (rated current) | |
THD | < 3% (rated power) | |
Power factor | 0.8 leading ~ 0.8 lagging | |
Withstanding voltage & insulation for AC output sides against the enclosure | Basic insulation 3000 Vdc / 1 min | |
EFFICIENCY | ||
Max. inverter efficiency | 98.7% | 98.9% |
Europe efficiency | 98.4% | 98.5% |
PROTECTIONS | ||
Input reverse connection protection | ●Yes | |
DC input switch | ●Yes | |
DC overvoltage and overload protection | ●Yes | |
Output AC short-circuit protection | ●Yes | |
AC overload, overcurrent limitation and protection | ●Yes | |
Grid over / under-voltage and unbalanced protection | ●Yes | |
Grid over / under-frequency protection | ●Yes | |
Leakage protection | ●Yes | |
Lightning protection | ●Yes | |
Islanding protection | Active and passive protection | |
DC surge protection | ●Yes | |
AC surge protection | ●Yes | |
Insulation resistance testing protection | ●Yes | |
CERTIFICATES AND APPROVALS | ||
Certificates | VDE / TUV / CE / CQC | |
Grid-connected standard | TUV / VDE-AR-N-4105 / G59 | |
EMC / safety | EN 61000-6-2, EN61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN / IEC 62109-1, EN / IEC 62109-2 | |
DISPLAY AND COMMUNICATIONS | ||
Display | LED indicators / Bluetooth / APP | |
RS485 | ●Yes | |
USB | ●Yes | |
PLC | Optional | |
APP and Bluetooth | ●Yes | |
OTHERS | ||
Standbyloss | < 15 W | |
Topology | Transformerless | |
MTBF | 40000 h | |
Warranty | 5 / 10 / 15 / 20 / 25 years optional | |
Operating temperature | – 25 °C ~ + 60 °C | |
Cooling | Natural cooling | |
Relative humidity | 0 ~ 100% non-condensing | |
IP rating | IP 65 | |
Max. operating altitude | 3000 m | |
Dimensions (W × D × H) (mm) | 260 × 580 × 800 | |
Packaged dimensions (W × D × H) (mm) | 690×935×345 | |
Net weight (kg) | ≤ 65 | |
Gross weight (kg) | < 70 |